Call 08048969305 100% Response Rate

Send Email

Rectus Steam Trap

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic trap, float trap & inverted bucket trap. There is huge difference in working principle of our RECTUS Steam trap and other ordinary steam trap.

There are mainly three problems in other mechanical operating traps are as under so preventive testing and maintenance required.

Traps fail in open condition :

  1. Wasting of steam, boiler feed water and treatment chemicals
  2. Also it creates back pressure on all other traps so stalling the condensate in other trap.

Traps fail in closed condition so backing up condensate causing:

  1. Loss of heat output
  2. Required Plant shut down and loss of production
  3. Water hammering in steam system and so plant damaged.


Working Principle

Steam is approximately 1000 times greater in volume than condensate at atmospheric pressure and as steam and condensate pass through the orifice of the trap. But in density wise condensate is much greater than steam so only condensate water come first than steam come out due to specifically sized venture orifice design.


It is important to know that acceptable loss from 50 RECTUS venturi orifice steam traps is LESS than that of 1 failed open mechanical type steam trap.

The RECTUS unit is sized to handle 100% of the condensate load produced by a particular application.

At 100% capacity, an accurately sized orifice loses no steam and backs up no condensate.

When the load drops below 100% capacity, the orifice passes a violently turbulent mixture of equivalent volumes of steam and water. Since condensate is several hundred times denser than steam, steam loss is negligible.

Best Indian Steam Traps For Steam
  • Best Indian Steam Traps For Steam
  • Best Indian Steam Traps For Steam
  • Best Indian Steam Traps For Steam
  • Best Indian Steam Traps For Steam
  • Best Indian Steam Traps For Steam
  • Best Indian Steam Traps For Steam
  • Best Indian Steam Traps For Steam
  • Best Indian Steam Traps For Steam
  • Best Indian Steam Traps For Steam
  • Best Indian Steam Traps For Steam

Best Indian Steam Traps For Steam

Product Price: Rs 6,000 / PieceGet Best Price

Product Brochure

Product Details:
SizeS/E 1/2",3/4",1",3/2",2"
ModelRECTUS 0.5,0.75,1.0,1.5,2.0
BrandInnovative Enerpro
MaterialBody SG Iron/ Internal part SS316
ColorBLACK
ConditionNew
Country of OriginMade in India

 

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1.                 Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2.                 Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in  Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

  Two orifice mechanism control condensate flow at all levels

  Tailor made Venturi orifice design control condensate flow automatically

  Continuous discharge of condensate

 

  Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

  Built in air vent for quick start up

  Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

  No SLR so no steam wastage due to miss setting of SLR

  Moving parts is rarely work and so no required maintenance for long time

  Permanently eliminate the need of steam trap survey and repairing cost

  CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

  Environment Friendly

  Save water and water treatment chemicals

  Permanent steam savings about 10 to 45%

  Increased heat transfer typically 10%

  Unaffected by thermal shock or water hammer so increasing plant life.

 

 

Get Best QuoteRequest A Callback
Steam Trap Valve
  • Steam Trap Valve
  • Steam Trap Valve
  • Steam Trap Valve
  • Steam Trap Valve
  • Steam Trap Valve
  • Steam Trap Valve
  • Steam Trap Valve
  • Steam Trap Valve
  • Steam Trap Valve

Steam Trap Valve

Product Price: Rs 6,000 / PieceGet Best Price

Product Brochure

Product Details:
SizeS/E 1/2,3/4,1,3/2,2
BrandIEPL
ModelRECTUS 0.5,0.75,1.0,1.5,2.0
MaterialBody SG Iron/ Internal part SS316
ColorBlack
Country of OriginMade in India

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1.                 Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2.                 Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in  Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

•  Two orifice mechanism control condensate flow at all levels

•  Tailor made Venturi orifice design control condensate flow automatically

•  Continuous discharge of condensate

 

•  Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

•  Built in air vent for quick start up

•  Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

•  No SLR so no steam wastage due to miss setting of SLR

•  Moving parts is rarely work and so no required maintenance for long time

•  Permanently eliminate the need of steam trap survey and repairing cost

•  CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

•  Environment Friendly

•  Save water and water treatment chemicals

•  Permanent steam savings about 10 to 45%

•  Increased heat transfer typically 10%

•  Unaffected by thermal shock or water hammer so increasing plant life.

 

Get Best QuoteRequest A Callback
Ball Float Steam Trap
  • Ball Float Steam Trap
  • Ball Float Steam Trap
  • Ball Float Steam Trap
  • Ball Float Steam Trap
  • Ball Float Steam Trap
  • Ball Float Steam Trap
  • Ball Float Steam Trap
  • Ball Float Steam Trap
  • Ball Float Steam Trap

Ball Float Steam Trap

Product Price: Rs 6,000 / PieceGet Best Price

Product Brochure

Product Details:
SizeS/E 1/2,3/4,1,3/2,2
ModelRECTUS 0.5,0.75,1.0,1.5,2.0
BrandInnovative Enerpro Pvt Ltd.
MaterialBody SG Iron/ Internal part SS316
ColorBlack
Country of OriginMade in India

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1.                 Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2.                 Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in  Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

  Two orifice mechanism control condensate flow at all levels

  Tailor made Venturi orifice design control condensate flow automatically

  Continuous discharge of condensate

 

  Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

  Built in air vent for quick start up

  Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

  No SLR so no steam wastage due to miss setting of SLR

  Moving parts is rarely work and so no required maintenance for long time

  Permanently eliminate the need of steam trap survey and repairing cost

  CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

  Environment Friendly

  Save water and water treatment chemicals

  Permanent steam savings about 10 to 45%

  Increased heat transfer typically 10%

  Unaffected by thermal shock or water hammer so increasing plant life.

 

Get Best QuoteRequest A Callback
IEPL Steam Traps
  • IEPL Steam Traps
  • IEPL Steam Traps
  • IEPL Steam Traps
  • IEPL Steam Traps
  • IEPL Steam Traps
  • IEPL Steam Traps
  • IEPL Steam Traps
  • IEPL Steam Traps
  • IEPL Steam Traps

IEPL Steam Traps

Product Price: Rs 6,000 / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Product Details:
Size1/2", 1", 1.5"
MaterialCast Iron
BrandIEPL
Model Name/NumberIepl Steam Trap
ColorBlack
Available DesignBall Float
Country of OriginMade in India
Rectus Steam Traps come standard with our 10 year performance guarantee against orifice erosion and steam wastage.

 

See below the smooth steam flow in RECTUS Steam trap compare to other mechanical steam trap.

 

Due to the traps unique orifice design there is TRUE continuous condensate discharge without any open/close cycles rather than intermittent discharge unlike traditional mechanical type steam traps.
It is important to know that acceptable loss from 50 Rectus steam traps is LESS than that of 1 failed open mechanical type steam trap. And CO2 emissions are reduced through reducing steam consumption and boiler fuel usage by up to 20¾nefits
  • Minimal Maintenance
  • No moving parts
  • No spare parts required
  • Permanently eliminate the need for steam trap surveys
  • Savings on labour for repairing steam traps
  • Unaffected by thermal shock or water hammer
  • Environmentally Friendly
  • CO2 emissions are reduced through reducing steam consumption and boiler fuel usage by up to 20%
  • Save water
  • Save water treatment chemicals
  • Save electricity
  • Handles varying or constant loads
  • Easily handles water hammer
  • Automatic air venting at start-up
  • Perfect operation in vertical or horizontal installation


Additional Information:

  • Production Capacity: 1000 per months
  • Delivery Time: 1 Week
Get Best QuoteRequest A Callback
Condensate Trap
  • Condensate Trap
  • Condensate Trap
  • Condensate Trap
  • Condensate Trap
  • Condensate Trap
  • Condensate Trap
  • Condensate Trap
  • Condensate Trap

Condensate Trap

Product Price: Rs 6,000 / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Product Details:
Size1/2" & 1" & 3/4" & 1.5" & 2"
BrandIEPL
Model Name/NumberIEPL
MaterialCAST IRON OR STAINLESS STEEL
I Deal InNew Only
ColorSILVER OR BLACK

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1.                 Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2.                 Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in  Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

•  Two orifice mechanism control condensate flow at all levels

•  Tailor made Venturi orifice design control condensate flow automatically

•  Continuous discharge of condensate

 

•  Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

•  Built in air vent for quick start up

•  Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

•  No SLR so no steam wastage due to miss setting of SLR

•  Moving parts is rarely work and so no required maintenance for long time

•  Permanently eliminate the need of steam trap survey and repairing cost

•  CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

•  Environment Friendly

•  Save water and water treatment chemicals

•  Permanent steam savings about 10 to 45%

•  Increased heat transfer typically 10%

•  Unaffected by thermal shock or water hammer so increasing plant life.

 



Additional Information:

  • Production Capacity: 100 PER MONTHS
  • Delivery Time: 2-5 DAYS
Get Best QuoteRequest A Callback
Mechanical Steam Trap
  • Mechanical Steam Trap
  • Mechanical Steam Trap
  • Mechanical Steam Trap
  • Mechanical Steam Trap
  • Mechanical Steam Trap
  • Mechanical Steam Trap

Mechanical Steam Trap

Product Price: Rs 6,000 / PieceGet Best Price

Product Brochure

Product Details:
ModelRECTUS 0.5,0.75,1.0,1.5,2.0
SizeS/E 1/2,3/4,1,3/2,2
BrandIEPL
MaterialBody SG Iron/ Internal part SS316
ColorBlack
Country of OriginMade in India

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1.                 Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2.                 Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in  Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

•  Two orifice mechanism control condensate flow at all levels

•  Tailor made Venturi orifice design control condensate flow automatically

•  Continuous discharge of condensate

 

•  Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

•  Built in air vent for quick start up

•  Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

•  No SLR so no steam wastage due to miss setting of SLR

•  Moving parts is rarely work and so no required maintenance for long time

•  Permanently eliminate the need of steam trap survey and repairing cost

•  CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

•  Environment Friendly

•  Save water and water treatment chemicals

•  Permanent steam savings about 10 to 45%

•  Increased heat transfer typically 10%

•  Unaffected by thermal shock or water hammer so increasing plant life.

 

Get Best QuoteRequest A Callback
Steam Condensate Trap
  • Steam Condensate Trap
  • Steam Condensate Trap
  • Steam Condensate Trap
  • Steam Condensate Trap
  • Steam Condensate Trap
  • Steam Condensate Trap

Steam Condensate Trap

Product Price: Rs 6,000 / PieceGet Best Price

Product Brochure

Product Details:
Model Name/NumberSTEAM TRAP, RECTUS 0.5,0.75,1.0,1.5,2.0
SizeS/E 1/2,3/4,1,3/2,2
BrandInnovative Enerpro Pvt Ltd.
MaterialBody SG Iron/ Internal part SS316
PressureAs per Requirement
Usage/Applicationdrain
Country of OriginMade in India

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1.                 Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2.                 Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in  Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

•  Two orifice mechanism control condensate flow at all levels

•  Tailor made Venturi orifice design control condensate flow automatically

•  Continuous discharge of condensate

 

•  Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

•  Built in air vent for quick start up

•  Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

•  No SLR so no steam wastage due to miss setting of SLR

•  Moving parts is rarely work and so no required maintenance for long time

•  Permanently eliminate the need of steam trap survey and repairing cost

•  CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

•  Environment Friendly

•  Save water and water treatment chemicals

•  Permanent steam savings about 10 to 45%

•  Increased heat transfer typically 10%

•  Unaffected by thermal shock or water hammer so increasing plant life.

 



Additional Information:

  • Production Capacity: 500 Per Months
  • Delivery Time: within 1 week
  • Packaging Details: -
Get Best QuoteRequest A Callback
Venturi Steam Traps
  • Venturi Steam Traps
  • Venturi Steam Traps
  • Venturi Steam Traps
  • Venturi Steam Traps
  • Venturi Steam Traps

Venturi Steam Traps

Product Price: Rs 6,000 / PieceGet Best Price

Product Brochure

Product Details:
ModelRECTUS 0.5,0.75,1.0,1.5,2.0
SizeS/E 1/2,3/4,1,3/2,2
BrandInnovative Enerpro Pvt Ltd.
MaterialBody SG Iron/ Internal part SS316
ColorBlack
Country of OriginMade in India

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1.                 Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2.                 Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in  Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

•  Two orifice mechanism control condensate flow at all levels

•  Tailor made Venturi orifice design control condensate flow automatically

•  Continuous discharge of condensate

 

•  Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

•  Built in air vent for quick start up

•  Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

•  No SLR so no steam wastage due to miss setting of SLR

•  Moving parts is rarely work and so no required maintenance for long time

•  Permanently eliminate the need of steam trap survey and repairing cost

•  CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

•  Environment Friendly

•  Save water and water treatment chemicals

•  Permanent steam savings about 10 to 45%

•  Increased heat transfer typically 10%

•  Unaffected by thermal shock or water hammer so increasing plant life.

 

Get Best QuoteRequest A Callback
Condensate Traps
  • Condensate Traps
  • Condensate Traps
  • Condensate Traps
  • Condensate Traps
  • Condensate Traps
  • Condensate Traps
  • Condensate Traps
  • Condensate Traps

Condensate Traps

Product Price: Rs 6,000 / PieceGet Best Price

Product Brochure

Product Details:
Model Name/NumberCAST IRON
Size1/2" & 1" & 3/4" & 1.5" & 2"
BrandIEPL
Usage/ApplicationA steam trap is a device used to discharge condensates and non-condensable gases with a negligible c
MaterialSS OR CI
ColorSILVER OR BLACK
I Deal InNew Only

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1.                 Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2.                 Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in  Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

•  Two orifice mechanism control condensate flow at all levels

•  Tailor made Venturi orifice design control condensate flow automatically

•  Continuous discharge of condensate

 

•  Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

•  Built in air vent for quick start up

•  Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

•  No SLR so no steam wastage due to miss setting of SLR

•  Moving parts is rarely work and so no required maintenance for long time

•  Permanently eliminate the need of steam trap survey and repairing cost

•  CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

•  Environment Friendly

•  Save water and water treatment chemicals

•  Permanent steam savings about 10 to 45%

•  Increased heat transfer typically 10%

•  Unaffected by thermal shock or water hammer so increasing plant life.

 



Additional Information:

  • Production Capacity: 100 PER MONTHS
  • Delivery Time: 2-5 DAYS
Get Best QuoteRequest A Callback
Condensate Steam Trap
  • Condensate Steam Trap
  • Condensate Steam Trap
  • Condensate Steam Trap
  • Condensate Steam Trap
  • Condensate Steam Trap

Condensate Steam Trap

Product Price: Rs 6,000 / PieceGet Best Price

Product Brochure

Product Details:
ModelRECTUS 0.5,0.75,1.0,1.5,2.0
SizeS/E 1/2,3/4,1,3/2,2
BrandInnovative Enerpro Pvt Ltd.
MaterialBody SG Iron/ Internal part SS316
ColorBLACK
Country of OriginMade in India

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1. Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2. Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

• Two orifice mechanism control condensate flow at all levels

• Tailor made Venturi orifice design control condensate flow automatically

• Continuous discharge of condensate

 

• Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

• Built in air vent for quick start up

• Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

• No SLR so no steam wastage due to miss setting of SLR

• Moving parts is rarely work and so no required maintenance for long time

• Permanently eliminate the need of steam trap survey and repairing cost

• CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

• Environment Friendly

• Save water and water treatment chemicals

• Permanent steam savings about 10 to 45%

• Increased heat transfer typically 10%

• Unaffected by thermal shock or water hammer so increasing plant life.

 

Get Best QuoteRequest A Callback
Float Trap
  • Float Trap
  • Float Trap
  • Float Trap
  • Float Trap

Float Trap

Product Price: Rs 60,000 / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Product Details:
ModelRECTUS 0.5,0.75,1.0,1.5,2.0, STEAM TRAP
SizeS/E 1/2,3/4,1,3/2,2
BrandInnovative Enerpro Pvt Ltd
MaterialBody SG Iron/ Internal part SS316
PressureNON IBR
Country of OriginMade in India

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1.                 Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2.                 Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in  Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

•  Two orifice mechanism control condensate flow at all levels

•  Tailor made Venturi orifice design control condensate flow automatically

•  Continuous discharge of condensate

 

•  Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

•  Built in air vent for quick start up

•  Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

•  No SLR so no steam wastage due to miss setting of SLR

•  Moving parts is rarely work and so no required maintenance for long time

•  Permanently eliminate the need of steam trap survey and repairing cost

•  CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

•  Environment Friendly

•  Save water and water treatment chemicals

•  Permanent steam savings about 10 to 45%

•  Increased heat transfer typically 10%

•  Unaffected by thermal shock or water hammer so increasing plant life.

 



Additional Information:

  • Production Capacity: 100 per months
  • Delivery Time: 1-2 week
  • Packaging Details: -
Get Best QuoteRequest A Callback
Ball Float Steam Trap
  • Ball Float Steam Trap
  • Ball Float Steam Trap
  • Ball Float Steam Trap
  • Ball Float Steam Trap
  • Ball Float Steam Trap
  • Ball Float Steam Trap
  • Ball Float Steam Trap
  • Ball Float Steam Trap

Ball Float Steam Trap

Product Price: Rs 6,000 / PieceGet Best Price

Product Brochure

Product Details:
SizeS/E 1/2,3/4,1,3/2,2
BrandIEPL
ModelSteam Traps
MaterialBody SG Iron/ Internal part SS316
ColorBlack
Country of OriginMade in India

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1. Steam traps fail in open condition ( Occur mostly in TD steam trap):

2. Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap)

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in Venturi Float Steam trap due to there are Ventury and float two orifice are in working.

In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

 Two orifice mechanism control condensate flow at all levels

 Tailor made Venturi orifice design control condensate flow automatically

 Continuous discharge of condensate

 

 Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

 Built in air vent for quick start up

 Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

 No SLR so no steam wastage due to miss setting of SLR

 Moving parts is rarely work and so no required maintenance for long time

 Permanently eliminate the need of steam trap survey and repairing cost

 CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

 Environment Friendly

 Save water and water treatment chemicals

 Permanent steam savings about 10 to 45%

 Increased heat transfer typically 10%

 Unaffected by thermal shock or water hammer so increasing plant life.

 

 



Additional Information:

  • Item Code: Rectus-Steam-Traps
Get Best QuoteRequest A Callback

EXPLORE MORE CATEGORIES

Contact Us
 
Thank youYour Enquiry has been sent successfully.
© Innovative Enerpro Private Limited. All Rights Reserved (Terms of Use)Developed and managed by IndiaMART InterMESH Ltd.