Innovative Enerpro Private Limited
Innovative Enerpro Private Limited
ISO 9001:2015 Certified
Isanpur, Ahmedabad, Gujarat
Send SMS
Send E-mail

RECTUS Steam Trap

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic trap, float trap & inverted bucket trap. There is huge difference in working principle of our RECTUS Steam trap and other ordinary steam trap.

There are mainly three problems in other mechanical operating traps are as under so preventive testing and maintenance required.

Traps fail in open condition :

  1. Wasting of steam, boiler feed water and treatment chemicals
  2. Also it creates back pressure on all other traps so stalling the condensate in other trap.

Traps fail in closed condition so backing up condensate causing:

  1. Loss of heat output
  2. Required Plant shut down and loss of production
  3. Water hammering in steam system and so plant damaged.


Working Principle

Steam is approximately 1000 times greater in volume than condensate at atmospheric pressure and as steam and condensate pass through the orifice of the trap. But in density wise condensate is much greater than steam so only condensate water come first than steam come out due to specifically sized venture orifice design.


It is important to know that acceptable loss from 50 RECTUS venturi orifice steam traps is LESS than that of 1 failed open mechanical type steam trap.

The RECTUS unit is sized to handle 100% of the condensate load produced by a particular application.

At 100% capacity, an accurately sized orifice loses no steam and backs up no condensate.

When the load drops below 100% capacity, the orifice passes a violently turbulent mixture of equivalent volumes of steam and water. Since condensate is several hundred times denser than steam, steam loss is negligible.


Request CallBack
  • Best Indian Steam Traps For Steam
  • Best Indian Steam Traps For Steam
Best Indian Steam Traps For Steam
Ask For Price

Best Indian Steam Traps For Steam

Product Price : Get Latest Price
Product Details:
ModelRECTUS 0.5,0.75,1.0,1.5,2.0
SizeS/E 1/2",3/4",1",3/2",2"
BrandInnovative Enerpro
MaterialBody SG Iron/ Internal part SS316
ConditionNew

 

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1.                 Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2.                 Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in  Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

•  Two orifice mechanism control condensate flow at all levels

•  Tailor made Venturi orifice design control condensate flow automatically

•  Continuous discharge of condensate

 

•  Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

•  Built in air vent for quick start up

•  Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

•  No SLR so no steam wastage due to miss setting of SLR

•  Moving parts is rarely work and so no required maintenance for long time

•  Permanently eliminate the need of steam trap survey and repairing cost

•  CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

•  Environment Friendly

•  Save water and water treatment chemicals

•  Permanent steam savings about 10 to 45%

•  Increased heat transfer typically 10%

•  Unaffected by thermal shock or water hammer so increasing plant life.

 

 


Yes! I am interested
View PDF
Request CallBack
  • float trap
  • float trap
float trap
Ask For Price

float trap

Product Price : Get Latest Price
Product Details:
SizeS/E 1/2,3/4,1,3/2,2
BrandInnovative Enerpro Pvt Ltd
MaterialBody SG Iron/ Internal part SS316
ModelRECTUS 0.5,0.75,1.0,1.5,2.0

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1.                 Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2.                 Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in  Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

•  Two orifice mechanism control condensate flow at all levels

•  Tailor made Venturi orifice design control condensate flow automatically

•  Continuous discharge of condensate

 

•  Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

•  Built in air vent for quick start up

•  Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

•  No SLR so no steam wastage due to miss setting of SLR

•  Moving parts is rarely work and so no required maintenance for long time

•  Permanently eliminate the need of steam trap survey and repairing cost

•  CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

•  Environment Friendly

•  Save water and water treatment chemicals

•  Permanent steam savings about 10 to 45%

•  Increased heat transfer typically 10%

•  Unaffected by thermal shock or water hammer so increasing plant life.

 


Yes! I am interested
View PDF
Request CallBack
  • steam condensate trap
  • steam condensate trap
steam condensate trap
Ask For Price

steam condensate trap

Product Price : Get Latest Price
Product Details:
SizeS/E 1/2,3/4,1,3/2,2
BrandInnovative Enerpro Pvt Ltd.
MaterialBody SG Iron/ Internal part SS316
ModelRECTUS 0.5,0.75,1.0,1.5,2.0

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1.                 Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2.                 Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in  Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

•  Two orifice mechanism control condensate flow at all levels

•  Tailor made Venturi orifice design control condensate flow automatically

•  Continuous discharge of condensate

 

•  Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

•  Built in air vent for quick start up

•  Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

•  No SLR so no steam wastage due to miss setting of SLR

•  Moving parts is rarely work and so no required maintenance for long time

•  Permanently eliminate the need of steam trap survey and repairing cost

•  CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

•  Environment Friendly

•  Save water and water treatment chemicals

•  Permanent steam savings about 10 to 45%

•  Increased heat transfer typically 10%

•  Unaffected by thermal shock or water hammer so increasing plant life.

 


Yes! I am interested
View PDF
Save time! Get the Best Deal

*Your information is safe with us.

Request CallBack
  • Steam Trap
  • Steam Trap
Steam Trap
Ask For Price

Steam Trap

Product Price : Get Latest Price
Product Details:
SizeS/E 1/2,3/4,1,3/2,2
BrandInnovative Enerpro Pvt Ltd.
MaterialBody SG Iron/ Internal part SS316
ModelRECTUS 0.5,0.75,1.0,1.5,2.0

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1.                 Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2.                 Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in  Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

•  Two orifice mechanism control condensate flow at all levels

•  Tailor made Venturi orifice design control condensate flow automatically

•  Continuous discharge of condensate

 

•  Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

•  Built in air vent for quick start up

•  Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

•  No SLR so no steam wastage due to miss setting of SLR

•  Moving parts is rarely work and so no required maintenance for long time

•  Permanently eliminate the need of steam trap survey and repairing cost

•  CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

•  Environment Friendly

•  Save water and water treatment chemicals

•  Permanent steam savings about 10 to 45%

•  Increased heat transfer typically 10%

•  Unaffected by thermal shock or water hammer so increasing plant life.

 


Yes! I am interested
View PDF
Request CallBack
  • venturi steam traps
  • venturi steam traps
venturi steam traps
Ask For Price

venturi steam traps

Product Price : Get Latest Price
Product Details:
SizeS/E 1/2,3/4,1,3/2,2
BrandInnovative Enerpro Pvt Ltd.
MaterialBody SG Iron/ Internal part SS316
ModelRECTUS 0.5,0.75,1.0,1.5,2.0

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1.                 Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2.                 Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in  Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

•  Two orifice mechanism control condensate flow at all levels

•  Tailor made Venturi orifice design control condensate flow automatically

•  Continuous discharge of condensate

 

•  Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

•  Built in air vent for quick start up

•  Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

•  No SLR so no steam wastage due to miss setting of SLR

•  Moving parts is rarely work and so no required maintenance for long time

•  Permanently eliminate the need of steam trap survey and repairing cost

•  CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

•  Environment Friendly

•  Save water and water treatment chemicals

•  Permanent steam savings about 10 to 45%

•  Increased heat transfer typically 10%

•  Unaffected by thermal shock or water hammer so increasing plant life.

 


Yes! I am interested
View PDF
Request CallBack
  • condensate steam trap
  • condensate steam trap
condensate steam trap
Ask For Price

condensate steam trap

Product Price : Get Latest Price
Product Details:
SizeS/E 1/2,3/4,1,3/2,2
BrandInnovative Enerpro Pvt Ltd.
MaterialBody SG Iron/ Internal part SS316
ModelRECTUS 0.5,0.75,1.0,1.5,2.0

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1. Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2. Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

• Two orifice mechanism control condensate flow at all levels

• Tailor made Venturi orifice design control condensate flow automatically

• Continuous discharge of condensate

 

• Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

• Built in air vent for quick start up

• Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

• No SLR so no steam wastage due to miss setting of SLR

• Moving parts is rarely work and so no required maintenance for long time

• Permanently eliminate the need of steam trap survey and repairing cost

• CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

• Environment Friendly

• Save water and water treatment chemicals

• Permanent steam savings about 10 to 45%

• Increased heat transfer typically 10%

• Unaffected by thermal shock or water hammer so increasing plant life.

 


Yes! I am interested
View PDF
Save time! Get the Best Deal

*Your information is safe with us.

Request CallBack
  • Steam Trap
  • Steam Trap
Steam Trap
Ask For Price

Steam Trap

Product Price : Get Latest Price
Product Details:
SizeS/E 1/2,3/4,1,3/2,2
MaterialBody SG Iron/ Internal part SS316
ModelSteam Traps

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1. Steam traps fail in open condition ( Occur mostly in TD steam trap):

2. Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap)

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in Venturi Float Steam trap due to there are Ventury and float two orifice are in working.

In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

• Two orifice mechanism control condensate flow at all levels

• Tailor made Venturi orifice design control condensate flow automatically

• Continuous discharge of condensate

 

• Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

• Built in air vent for quick start up

• Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

• No SLR so no steam wastage due to miss setting of SLR

• Moving parts is rarely work and so no required maintenance for long time

• Permanently eliminate the need of steam trap survey and repairing cost

• CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

• Environment Friendly

• Save water and water treatment chemicals

• Permanent steam savings about 10 to 45%

• Increased heat transfer typically 10%

• Unaffected by thermal shock or water hammer so increasing plant life.

 

 


Additional Information:
  • Item Code: Rectus-Steam-Traps
Yes! I am interested
View PDF
Request CallBack
  • steam trap valve
  • steam trap valve
steam trap valve
Ask For Price

steam trap valve

Product Price : Get Latest Price
Product Details:
SizeS/E 1/2,3/4,1,3/2,2
MaterialBody SG Iron/ Internal part SS316
ModelRECTUS 0.5,0.75,1.0,1.5,2.0

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1.                 Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2.                 Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in  Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

•  Two orifice mechanism control condensate flow at all levels

•  Tailor made Venturi orifice design control condensate flow automatically

•  Continuous discharge of condensate

 

•  Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

•  Built in air vent for quick start up

•  Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

•  No SLR so no steam wastage due to miss setting of SLR

•  Moving parts is rarely work and so no required maintenance for long time

•  Permanently eliminate the need of steam trap survey and repairing cost

•  CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

•  Environment Friendly

•  Save water and water treatment chemicals

•  Permanent steam savings about 10 to 45%

•  Increased heat transfer typically 10%

•  Unaffected by thermal shock or water hammer so increasing plant life.

 


Yes! I am interested
View PDF
Request CallBack
  • condensate trap
  • condensate trap
condensate trap
Ask For Price

condensate trap

Product Price : Get Latest Price

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1.                 Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2.                 Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in  Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

•  Two orifice mechanism control condensate flow at all levels

•  Tailor made Venturi orifice design control condensate flow automatically

•  Continuous discharge of condensate

 

•  Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

•  Built in air vent for quick start up

•  Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

•  No SLR so no steam wastage due to miss setting of SLR

•  Moving parts is rarely work and so no required maintenance for long time

•  Permanently eliminate the need of steam trap survey and repairing cost

•  CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

•  Environment Friendly

•  Save water and water treatment chemicals

•  Permanent steam savings about 10 to 45%

•  Increased heat transfer typically 10%

•  Unaffected by thermal shock or water hammer so increasing plant life.

 


Yes! I am interested
View PDF
Save time! Get the Best Deal

*Your information is safe with us.

Request CallBack
  • mechanical steam trap
  • mechanical steam trap
  • mechanical steam trap
mechanical steam trap
Ask For Price

mechanical steam trap

Product Price : Get Latest Price
Product Details:
SizeS/E 1/2,3/4,1,3/2,2
MaterialBody SG Iron/ Internal part SS316
ModelRECTUS 0.5,0.75,1.0,1.5,2.0

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1.                 Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2.                 Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in  Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

•  Two orifice mechanism control condensate flow at all levels

•  Tailor made Venturi orifice design control condensate flow automatically

•  Continuous discharge of condensate

 

•  Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

•  Built in air vent for quick start up

•  Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

•  No SLR so no steam wastage due to miss setting of SLR

•  Moving parts is rarely work and so no required maintenance for long time

•  Permanently eliminate the need of steam trap survey and repairing cost

•  CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

•  Environment Friendly

•  Save water and water treatment chemicals

•  Permanent steam savings about 10 to 45%

•  Increased heat transfer typically 10%

•  Unaffected by thermal shock or water hammer so increasing plant life.

 


Yes! I am interested
View PDF
Request CallBack
  • condensate traps
  • condensate traps
condensate traps
Ask For Price

condensate traps

Product Price : Get Latest Price

Main function of any steam trap is to trap the steam and drain out the condensate water. In industry there are many types of steam trap like thermodynamic steam trap, float steam trap, inverted bucket steam trap & Venturi Orifice steam trap. There is huge difference in working principle of Venturi float Steam trap and other regular steam trap.

 

There are mainly two problems in other regular mechanical operating steam traps are as under so preventive testing and maintenance required frequently.

 

1.                 Steam traps fail in open condition ( Occur mostly in TD steam trap):

 

2.                 Steam traps fail in closed condition so backing up condensate causing (Occur mostly in Float and Bucket steam trap):

Note : In float steam trap there are permanent steam loss through SLR.

 

All these problems are eliminated in  Venturi Float Steam trap due to there are Ventury and float two orifice are in working.



In Venturi float Steam Trap there are two orifice working to remove condensate from Steam System. One is Venturi orifice which is design as per client condensate load and pressure at inlet of trap and second is float valve orifice. Ventury orifice nozzle is sized to handle 100% of the condensate load produced by a particular application. Normally ventury orifice is in working condition. Float orifice is in closed condition. Some time at starting of process and low pressure condition there are float orifice is open and remove excess water from system. So this Venturi Float steam trap can cope up efficiently the condensate load at start up, normal running and pick load condition.

DESIGN FEATURES

•  Two orifice mechanism control condensate flow at all levels

•  Tailor made Venturi orifice design control condensate flow automatically

•  Continuous discharge of condensate

 

•  Efficient condensate discharges due to 0.001 kg/cm2 differential pressure against 0.1 kg/cm2 of other make trap

•  Built in air vent for quick start up

•  Wear resistance construction as SG iron cover and base & stainless steel internals part

Advantages and Benefits

•  No SLR so no steam wastage due to miss setting of SLR

•  Moving parts is rarely work and so no required maintenance for long time

•  Permanently eliminate the need of steam trap survey and repairing cost

•  CO2 emissions are reduced through reducing steam consumption and boiler fuel usage.

•  Environment Friendly

•  Save water and water treatment chemicals

•  Permanent steam savings about 10 to 45%

•  Increased heat transfer typically 10%

•  Unaffected by thermal shock or water hammer so increasing plant life.

 


Yes! I am interested
View PDF

Explore more products

X